Note: The question May Not state “Refer to the FDNY Reference Guide/Material.”

On a Fire Alarm System, when would you visually inspect Nickel-Cadmium Batteries?                                  
C             p. 2
  1. Weekly
  2. Monthly
  3. Semiannually 
  4. Quarterly

 

2)        How often must you visually inspect manual fire alarm boxes (manual pull stations) of a fire alarm system?                A         p. 3

  1. Semiannually
  2. Quarterly
  3. Daily
  4. Monthly

 

3)        For standpipe systems, when should the temperature alarms (cold weather) in a water storage tank be tested?                    A            p. 12

  1. Monthly
  2. Weekly
  3. Quarterly
  4. Daily

 

4)        For a fire alarm system, how often must interface equipment such as the fail-safe system be tested?                                       B            p. 6    

  1. Weekly
  2. Annually
  3. Semiannually 
  4. Monthly

 

5)        If a building has a 400 head sprinkler system, how many spare heads must be kept on the premises?                         C         p. 7

  1. 150
  2. 400
  3. 12
  4. 24

 

6)        On a standpipe system, how frequent must a Trip test be performed on a Quick Opening Device?                                            D            p. 12

  1. Quarterly 
  2. Monthly
  3. Every 5 years
  4. Annually

 

7)        On a sprinkler system, when must the Water Motor Gong alarm system be tested?                                                          B         p. 8

  1. Monthly
  2. Quarterly
  3. Semiannually
  4. Every 5 years

 

8)        When is a Wet Chemical Fire Extinguishing System required to be tested?            A         p. 13

  1. Semiannually
  2. Annually 
  3. Quarterly
  4. Monthly

 

9)        If an individual enters your premises to inspect your commercial kitchen exhaust system, they must possess what certification?             C         pp. 1 & 16

  1. A) T-89
  2. B) S-95
  3. C) P-64
  4. D) F-60

 

10)      The initial fire safety training provided to a Building Evacuation Supervisor for should be how long in duration?                      D            p. 1

  1. 1 hour
  2. 30 minutes 
  3. Varies based on their prior experience 
  4. 2 hours

 

11)      For a sprinkler system in a commercial, high rise office building which of the following individuals may perform the annual test of the pressure reducing and relief valves?                                D         p. 9 (MP residential only w/ 30 heads or less)

  1. Holder of a S-12 C of F only
  2. Engineer with a S-12
  3. Master Plumber with a S-12
  4. Master Fire Suppression Piping Contractor with a S-12